Independent testing

Results of testing by professional independent institutions

Functional coatings FN NANO® were tested by a number of Czech and foreign independent professional institutions for their functionality, efficiency and safety in terms of the applicable standards. Below you can find the published results of this testing which demonstrate the high efficiency, functionality and security of our coatings both in terms of the applicable building, technical and health standards, as well as their photocatalytic efficacy and other characteristics associated with their practical use.

The photocatalytic efficiency


I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

VŠCHT - Test of Photocatalytic Activity using ISO standard(Cz)

VŠCHT

– Determination of photocatalytic activity, removal of formaldehyde.

University of Chemical Technology, Prague – Determination of photocatalytic activity of FN® 1 – 3 according to ISO – formaldehydes


Anti Bacterial Test of FN NANO® and FN NANO® for removal of bacteria MRSA, Escherichia coli and Salmonella. Excellent results.

 

FINAL REPORT ANTIMIKROBIAL TEST

VŠCHT: Pollutant Degredation

VŠCHT – TECHNOPARK Kralupy: Pollutant degradation

Laboratory protocol at the University of Chemistry and Technology, Prague – testing of FN ® – pollutant degradation from air according to ISO standards: the protocol demonstrates high efficiency of FN ® coatings in the degradation of NOx, acetaldehyde, formaldehyde and toluene.


VŠCHT: Degredation of VOCs and Hexane

VŠCHT: VOC degradation tests (hexane)

The tests confirmed the very good ability of FN ® 2 to degrade hexane.


Scientific articles and publications on FN NANO® technology

NOx REMOVAL FROM THE AIR

Czech Academy of Sciences – J. Heyrovsky Institute of Physical Chemistry – Rathousky, Zouzelka: NOx Removal from the Air (scientific article)

Scientists from the Academy of Sciences of the Czech Republic, who have long been involved in the study of photocatalysis, have published their conclusions on long-term testing of the effectiveness of FN NANO® coatings in removing nitrogen oxides from the air. The paper concludes that FN NANO® coatings are a promising environmental technology capable of effectively purifying air from a significant pollutant – nitrogen oxides.

EFFECT OF AIR VELOCITY ON NOx REMOVAL FROM AIR

Czech Academy of Sciences – J. Heyrovsky Institute of Physical Chemistry – E. Mikyskova, I. Martiniakova, R. Zouzelka, J. Rathousky: Effect of air velocity on NOx removal from air (scientific article)

The work continues and further expands the research of scientists from the Czech Academy of Sciences. The scientific article describes the effects of different weather conditions on the effectiveness of FN NANO® coatings, especially air speed and flow rate. The results demonstrated the high efficiency of these coatings even under demanding flow conditions. A high effect on the reduction of NO and also NO2 was shown.

REMOVING POLLUTION AND EMISSIONS FROM THE AIR

Czech Academy of Sciences – J. Heyrovsky Institute of Physical Chemistry – R. Zouzelka, I. Martiniakova, T. Duchacek, B. Muzikova, E. Mikyskova, J. Rathousky: Removing Pollution and Emissions from Air, Focusing on Mixtures of Pollutants (scientific article)

Another scientific publication deals with the use of FN NANO® coatings for effective reduction of pollution and emissions from the air. Outdoor air contains many pollutants such as inorganic nitrogen oxides (NOx), sulfur oxides (SOx) and nitrogen oxide (CO) and ozone (O3), as well as organic and carcinogenic compounds (VOC). The study concludes that the removal efficiency of individual pollutants is not greatly affected when the pollutants are in a mixture. It is therefore possible to model the photocatalytic process even for real conditions based on laboratory measurements.


Protocol from Institute of Physical Chemistry (ÚFCH AV ČR)

J. Heyrovsky Institute of Physical Chemistry, Academy of Sciences of the Czech Republic: Protocol of photocatalytic activity of paint samples FN ® 2 from noise barrier

The Institute of Chemical Technology has tested samples from the test wall on which Advanced Materials-JTJ has been testing for a long time, in conditions of high air pollution, the functionality of coatings (high-traffic four-lane highway intersection with 30,000 cars per day). After two years, the tests proved to maintain high photocatalytic efficiency (the same as for the a new coating).


Safety Assessment of Coatings:


Opinion from Health Institute (ZU) Ústí nad Labem

Expert judgment on public health protection

The document states that in terms of Act No. 258/2000 Coll. the protection of public health is suitable, “stated that the handling of products” (FN ®  1-3) “can be considered safe” .


Zpráva VŠB (Technical University of Ostrava: Report)

VŠB – Technical University of Ostrava: Report on the Measurement of Nano and Micro-Particles in the Working Environment of the Paskov Preschool (FN ®Coating Application Tests )

The report concludes that: “The results of the subsequent analysis of captured aerosol indicate that no significant Titanium representation was found in the composition . The observed concentrations of titanium (if detected) do not exceed background levels commonly found in aerosol in the atmosphere. “In conclusion, therefore effectively it states that in the rooms where they are applied coatings in fact there is no release of nanoparticle TiO2 FN ® coating layer to the room kindergarten. Otherwise, this would necessarily result in an increase in the measured amount of Ti.


SZU Opinion (State Health Institute)

EAA: Ecotoxicity and phototoxicity

The EAA expert report shows that the toxicity of the FN ®  2  coating without UV irradiation is significantly low . Covering microscopic organisms only shows more significant toxicity when irradiated with UV light . At the same time, tests have shown that no higher toxicity (fish) has been observed even at an extreme concentration of 250 ml FN ® / 1000 ml water .


SZU Opinion (State Health Institute)

SZÚ: Sensory Test Protocol (Additional Information on FN ®  Use in Food Industry)

The protocol shows that the use of coatings do not affect the sensory properties of food.


SZU: Sensory test results from NATIONAL INSTITUTE OF PUBLIC HEALTH (OF THE CZECH REPUBLIC)

National Reference Laboratory  National Reference szo for food contact materials and for products for children under 3 years


Antimicrobial efficacy:


SZU Opinion (State Health Institute)
MSL Final Report

SZÚ: Protocol of bactericidal and virucidal activity tests of FN ® 2

Tests have demonstrated high bactericidal and virucidal efficacy of FN ®  2 on UV activation.

ISO Test for Antimicrobial Activity of FN2 and FN3

Test performed by EMSL laboratory in Houston, Texas, according ISO Method 27447 proving eradication of AMRSA, Escherichia Coli and Salmonella, with excellent results.


Table ABT

Summary table for testing bactericidal and virucidal efficacy of FN ®

The high bactericidal and virucidal efficacy of FN ®  2 coatings has been demonstrated by a number of health care institutions.


Wall Sample-Smears at Kladno Hospital

Testing Institute Ústí nad Labem: Comparison of bacterial levels on walls with and without FN ®  coatings

The comparison was made using swabs. The results show that FN ®  coating effectively prevents the build-up of bacteria on the walls where it is applied.  


SZU Opinion (State Health Institute)

Testing Institute of Ostrava: Testing of antimicrobial properties of FN ®

ZÚ Ostrava – results of testing of antimicrobial properties of FN ® 1-3 against filamentous fungus “Aspergillus brasiliensis”


SZU Opinion (State Health Institute)

SZÚ: Antimicrobial Activity of FN ®  Biomax

SZÚ – Determination of antimicrobial activity – FN ® Biomax 1 and 2


More tests and protocols:


TZÚS Protocol (Technical and Test Institute for Construction)

TZÚS – Product Certification Result Report (FN ® 1,2,3)

The protocol contains specific data on properties, documents and legal standards on the basis of which FN ® coatings were certified by TZÚS. Certified properties: adhesion, frost resistance, health harmlessness, reduction of viruses and bacteria. FN ® 1,2,3 complies with all applicable standards and standards.


TZÚS Protocol (Technical and Test Institute for Construction)

The protocol demonstrates the high vapor permeability of FN ® 2


LCA study CTU Prague (Faculty of Mechanical Engineering)

CTU, Faculty of Mechanical Engineering, Department of Business Management and Economics: “Comparative LCA Study FN2 and Air Purifier”

The study comprehensively assesses the life cycle impacts (from production and processing of raw materials to the product, its use to disposal) to the environment. The conclusion of this paper states: “Based on this study, the use of FN2 photocatalytic coating is considerably more environmentally friendly than using an air purifier.”


NOTICE: The company has re-branded the registered FN® brand for commercial reasons on the 1. 10. 2021. Currently, two registered brands are used, the international FN NANO®  and the Czech FN®. It has simplified the trade name by deleting the word “Protectam” and uses the designations FN® 1, FN® 2 and FN® 3 or newly FN NANO® 1, FN NANO® 2, FN NANO® 3, FN NANO® BioMax, FN NANO® Wood and FN NANO® Aqua. In addition to the basic product designation functional coatings FN®, all documents also mention the trade name Protectam, which is no longer in use and will be gradually replaced by the above-mentioned simplified name FN NANO®.